A new TPO roof can look finished from the parking lot while the details that keep water out are still hard to judge. You can see the white membrane. You can’t see whether the seams fused properly, whether the attachment matches the building’s wind exposure, or whether water will reach the drains after heavy rain.
Those details matter whether you manage an office, a retail space, an apartment complex, or another building with a low-slope roof. This guide explains what to look for in the membrane, seams, attachment, flashing, and drainage. For TPO roofing in East Lansing, MI, call Armor Commercial Roofing at (517) 617-6953 to discuss your building and schedule a roof assessment.
Brochure Claims vs. What Actually Gets Built
Product literature often emphasizes reflectivity, durability, and low maintenance. Those are useful starting points. What you get on your building depends on the complete roof system and how it’s installed.
- Reflectivity: A reflective membrane can reduce the heat the roof absorbs in summer. The effect on energy use depends on insulation, HVAC equipment, and how the building is used.
- Durability: Membrane thickness, rooftop traffic, installation quality, and upkeep all affect service life. A thicker sheet can’t make up for an open seam or poorly sealed curb.
- Maintenance: Drains still need clearing, seams and flashing need periodic checks, and rooftop service work can damage even a newer membrane.
Use the written proposal to compare details you can verify: the membrane, how it will be held in place, how seams and flashing will be checked, and what work is included to improve drainage.
The Membrane: Picking the Right Sheet
TPO comes in several thicknesses and colors. Start with how the roof is used and what the complete system needs to do.
How Thick Should It Be?
Common options include 45, 60, and 80 mil. One mil is one-thousandth of an inch. A thicker sheet can provide more material above the reinforcing fabric. A 60-mil membrane is a common commercial option. An 80-mil sheet may be worth considering where service traffic is frequent or where the proposed warranty requires it. Compatible walkway pads can help protect the routes crews use to reach equipment.
Is It Reinforced?
Commercial TPO commonly contains a reinforcing fabric called a scrim. It helps resist tearing, including where a mechanically attached sheet transfers loads to fasteners.
What Color?
White is common when reflectivity matters. Some products are also available in gray or tan. Compare the published reflectance ratings for the specific product and color rather than judging performance by appearance alone.
Is the System Matched?
The membrane, flashings, adhesives, primers, and edge accessories need to work together. Ask which components the manufacturer approves for the proposed assembly and which are required for the warranty. Armor’s guide to TPO roof installation in Wyoming, MI covers additional questions to ask before approving an installation.
Seams: Welded and Then Verified
TPO sheets overlap at their edges. A hot-air welder heats the surfaces at the overlap so they fuse. Automatic welders can handle long, straight runs, while hand welders are useful at corners and in tight areas. A seam can look clean from above and still have a gap underneath.
Prepare the Surface
A clean, dry overlap helps the two sheets bond. Dirt, dew, or surface residue can interfere with the weld.
Weld Test Strips
Sample welds help establish the settings before production welding. The sample is checked against the manufacturer’s instructions before those settings are used on the roof.
Adjust as Conditions Change
Roof temperature, wind, and sunlight can change how quickly the membrane heats up. A new test weld can help determine whether the heat or travel speed needs to change.
Weld to the Required Width
The fused area should meet the selected manufacturer’s minimum weld width.
Probe the Cooled Seams
Once the weld has cooled, a seam probe can help find gaps or sections that didn’t fully fuse. Any defects found should be corrected and checked again.
Where three sheets overlap, a small step forms at the T-joint. Follow the membrane manufacturer’s detail, including a cover patch where specified.

Attachment: Holding the Roof in Place
The right attachment method depends on the deck, insulation, building height, wind exposure, and the requirements of the proposed assembly.
Mechanically Attached
In a system fastened at the seams, screws and plates secure the membrane to the deck. The next sheet overlaps the fastener row and is welded over it. The wind design determines the fastener layout, including any additional securement at edges and corners.
Fully Adhered
Adhesive bonds the membrane to an approved cover board or insulation surface. The adhesive’s temperature and surface requirements can affect when work can proceed.
Induction-Welded
Special plates are fastened to the deck beneath the membrane. An induction tool bonds the sheet to the plates from above without fasteners passing through the finished membrane at those points.
The proposed attachment should account for the insulation and cover board as well as the membrane. Wind resistance depends on how the entire assembly is secured.
Penetrations: Sealing Every Interruption
Pipes, HVAC curbs, walls, and edges interrupt the roof surface. Flashing connects those features to the membrane so water can move past them without getting underneath.
- Pipes and vents: Where suitable, a preformed TPO boot is welded at the base and secured at the top as specified.
- HVAC and equipment curbs: Flashing covers the curb faces and corners, with the top secured according to the assembly detail.
- Irregular penetrations: Grouped conduit or odd-shaped supports may need custom flashing or an approved sealant pocket.
- Walls and parapets: Flashing extends up the wall and is secured and protected with the specified termination, counterflashing, or coping.
- Roof edges: Compatible edge metal and membrane details help seal the perimeter and resist wind uplift.
Ask how the proposal handles the curbs, pipes, and other openings on your roof and how those details will be checked before the job is closed out.
Drainage: Moving Water Before It Freezes
Even a well-welded membrane needs a clear path for runoff. In East Lansing, snowmelt can refreeze around drains and slow the next round of runoff. A drainage plan can include:
- Tapered insulation that creates slope toward drains or scuppers
- Crickets, or raised sections, that direct water around curbs or between drains
- Drain sumps that lower the roof surface immediately around an outlet
- Sealed membrane connections, with a clamping ring where the drain design calls for one
- Scuppers and downspouts sized for the building’s drainage needs
On replacement projects, dirt rings and debris lines can show where water has collected. Compare those clues with the actual roof slope and outlet locations before deciding what needs to change.

What to Look for in a TPO Proposal
When comparing proposals, look for these details in writing:
- The membrane manufacturer, product, thickness, and color
- The attachment method and how it accounts for wind exposure
- How seams will be welded and checked
- How pipes, curbs, walls, and roof edges will be flashed
- Any drainage changes, such as tapered insulation, crickets, or new outlets
- Which components are approved for the assembly and what the warranty requires
These details help you compare what each contractor plans to build and see whether both proposals address the same problems.
Schedule TPO Roofing in East Lansing, MI
If you’re planning a new roof or replacing an existing one, bring any recurring leak locations, drainage concerns, and rooftop equipment plans to the assessment. These details help shape the membrane, attachment, and flashing choices.
Call Armor Commercial Roofing at (517) 617-6953 to schedule a roof assessment for your commercial building in East Lansing, MI.
FAQ
Which TPO thickness is right for my building?
A 60-mil membrane is a common commercial option. An 80-mil sheet may be worth considering where rooftop service traffic is frequent or when required by the proposed warranty. Compare the complete assembly and ask about walkway protection near equipment.
How are TPO seams tested?
Test welds help establish welding settings and check them when conditions change. After a finished weld cools, a seam probe can help locate gaps or incomplete fusion. The manufacturer’s instructions guide how these checks are performed.
What’s the difference between mechanically attached and fully adhered TPO?
A mechanically attached system secures the membrane with fasteners and plates. A fully adhered system bonds the membrane to an approved surface with adhesive. The right choice depends on the deck, insulation, wind design, and project conditions.
Where do most TPO leaks start?
Open seams, pipe boots, HVAC curb flashing, wall transitions, roof edges, and drain connections are common places to check. The point where water appears inside may be some distance from where it entered.
Does a white TPO roof guarantee lower energy bills?
No. A reflective surface can reduce summer heat gain, but the impact on energy bills depends on insulation, HVAC equipment, and how the building is used.